Electrical Product with Iron Core II 1. Iron Core Reactor Product Model and Performance Parameter Product features of dry-type iron -core reactor: Product features of oil-immersed iron -core reactor: The volume is small and the appearance is nice; the loss is low and the operation is economic;...

Chat Now

    Electrical Product with Iron CoreII 


    1. Iron Core Reactor

    The serialized product research on 34 specifications of resin-cast dry-type iron core reactors and oil-immersed iron-core shunt reactors have been completed. The first 35kV 15000kvar dry-type iron-core shunt reactors with the maximum capacity developed autonomously has passed the product certification of China Electric Power Research Institute. The product is equipped with stable performance and low noise after being put into operation and its temperature rise is superior to the national standard.


    图片20.jpg


    ● Product Model and Performance Parameter

    Product Name

    Product Model

    Performance Parameter

    Iron-core shunt reactors

    BKSC Dry-type Series

    (Arranged in a line or a triangle)

    The voltage class is 6~35kV and the rated capacity is 1000~15000kvar, which is the three-phase system or single-phase one.

    BKSJ Oil-immersed Series

    The voltage class is 6~66kV and the rated capacity is 1000~60000kvar, which is the three-phase system or single-phase one.

    Iron-core Series reactors

    CKSC Dry-type Series

    The voltage class is 6~35kV and the rated capacity is 18~1800kvar, which is the three-phase system or single-phase one.

    CKSJ Oil-immersed Series

    The voltage class is 6~66kV and the rated capacity is 30~7200kvar, which is the three-phase system or single-phase one.

     

    ● Product features of dry-type iron-core reactor:

    图片21.jpgThe dry-type product adopts the epoxy cast insulation system with no oil medium and excellent safety; the class of the coil for insulation and heat resistance is F, and the coil is casted into a solid entirety; the silicon sheet is taken as the magnetic conductance and the iron core is taken as the magnetic conductance return circuit for magnetic flow, which causes no electromagnetic pollution to the surroundings and is suitable for the indoor transformer substation of city use. The iron core post is casted into molding as a whole, which becomes a solid rigid body with small vibration and low noise during operation; it is also equipped with small volume, light weight and nice appearance.


    ● Product features of oil-immersed iron-core reactor: 

    The volume is small and the appearance is nice; the loss is low and the operation is economic; the reactor takes the iron core as the magnetic conductance return circuit, which causes no electromagnetic pollution to the surroundings with low noise, small vibration, low temperature rise and strong acclimatization ability, and it can be operated out of door.图片22.jpg


    ● Iron-core shunt reactors: 

    图片23.jpg

    As the continuous expansion of our city departments and the transformation of the city power grid, the overhead line is gradually substituted by the buried cable, which makes the current charged with ground capacitance in the transmission network increase rapidly. To reduce the withstand voltage of the power frequency and insulation level in the system so as to ensure the safe and reliable operation in the system and the power supply quality of the city power grid, it is universally applied in the city distribution network.


    ● Iron-core Series reactors: 

    The series reactors are generally series in the high-voltage power capacitor or return circuit of the capacitor bank with the main functions of restraining the higher harmonic, reducing the undue distortion of the network voltage waveform, limiting the flashy flow of the capacitor during phase-splitting switching, etc. As the continuous development of the power grid, the series reactors are used more and more widely as the indispensible equipment in the reactive compensation device.图片24.jpg


    2. Arc Suppression Coil

    图片25.jpghe arc suppression coil is the single-phase reactor which is adjustable with electrical inductance. When it is under the multi-tap model, the capacity of the compensating current can be changed through the control of the inserted tapping point position with the on-load switch; and when it is under the tuning capacitor condition, the inductance current of the main winding can be adjusted through the change of the capacitance in the low-voltage winding of the arc suppression coil. The arc suppression coil is equipped with the secondary winding to be inserted into the damping resistance.


    ● Product Model and Performance Parameter

    Product Model

    Performance Parameter

    XDZC and XDCR Dry-type Series

    The voltage class is 6~35kV and the rated capacity is 27~4200kvar

    XDZJ and XDJR Oil-immersed Series

    The voltage class is 6~66kV and the rated capacity is 27~6500kvar


    ● Technology Feature

    The dry-type series adopt the epoxy cast insulation system with no oil medium and excellent safety. The class of the coil for insulation and heat resistance is F, and the coil is casted into a solid entirety; the oil-immersed series iron eddy current is provided with small loss, low noise, and small volume, which can be used out of door with strong acclimatization ability. It takes the lead domestically.图片26.jpg

     

    When the single-phase ground fault takes place in the three-phase electrical power system, the inductance current will be generated in the arc suppression coil to offset the capacitance current caused by the ground capacitance of the line, eliminating the continuous arc of the fault point due to the existence of the capacitance current, avoiding the expansion of the fault scope and improving the safety and reliability of the power supply system. It is suitable to the isolated neutral system with the voltage class of 6~66kV nationwide and under 33kV abroad.


    3. Earthing Transformer

    图片27.jpgFor the power grid without the neutral point, the man-made neutral point can be provided by the Earthing Transformer for the power grid. The main winding of the Earthing Transformer adopts the “Z” connection mode with low zero-sequence impedance; it is generally equipped with the secondary (Low voltage) winding to provide power for the local auxiliary load. The rated capacity of the main winding is generally larger than the secondary one.


    ● Product Model and Performance Parameter

    Product Model

    Performance Parameter

    DSBC Dry-type Series

    The voltage class is 6~35kV and the rated capacity is 27~4200kvar

    BSBJ Oil-immersed Series

    The voltage class is 6~66kV and the rated capacity is 27~6500kvar


    The dry-type series adopts the epoxy cast insulation system with no oil medium and good safety. The class of integral insulation and heat resistance is F, and the coil is casted into a solid entirety. If is equipped with the secondary winding, to use the transformer in the substituting station can reduce the investment with small floor area, which is suitable for the city transformer substation. The oil-immersed type series can be used out of door which is equipped with a strong acclimatization ability.

    The Earthing Transformer is used to provide a ground neutral point for the three-phase power grid, which can be connected to the ground directly, through the arc suppression coil, through the small resistance and by the current-limiting reactor. It is suitable to the isolated neutral system with the voltage class of 6~66kV inland and under 33kV abroad.

    图片28.jpg

     

    4. Complete Device of Automatic Following 

    图片29.jpgThe arc suppression coil, Earthing Transformer and complete device of automatic tracking line-selection is a new integrated intelligent device, gathering the capacitance current of the automatic real-time following and compensation power grid and the single-phase grounding line-selection as a whole. The device can automatically measure the capacitance current of the system in real-time during the normal operation of the system; the equipment will be automatically under the compensation condition when the system under single-phase grounding, and will output the inductive compensated current that is relative to the capacitance current of the system single-phase grounding between the neutral point and ground in the system to limit the grounding current and eliminate the ground arc; and the equipment will quit the compensation condition after the ground fault is eliminated.


    ●Product Model and Performance Parameter

    Product Model

    Performance Parameter

    ZDTB Series

    The error of the measurement accuracy on the capacitance current is less than ±2%; the compensating current in place: Reach 10µs; the voltage of the neutral point: Less than 5% of the phase voltage during normal operation; the accuracy rate of the line selection: 100%.

     

    The key material accessories and production equipment of the device are all imported from abroad, and combined with the advanced processing and manufacturing engineering. High safety: The damping resistance is installed in the secondary side of the arc suppression coil, and adopts the controllable silicon to switch the damping resistance; Good damping resistance effect: During the automatic tuning process, the damping resistance is changed with the turns number of the coil at direct ratio with a constant damping ratio that is always under the best damping effect; Excellent measurement and tracking method: The Calculation of the whole measurement and tracking adopts the ratio between the same signal and the two measurements as the basic parameter, avoiding the unstable result due to the error and change of the measurement channel; Line-selection support: The single controller can work in one control and one busbar section, and it can support 4 busbar sections at most with 48 ways of each busbar section; Convenient operation: The operation of the controller adopts the touch screen and supports the manual operation. The user interface is the Windows style with quick configuration and reference. The multicolor LCD is allocated; the capacity of the historical data base for record, reference and derivation of the historical data is large (Reach 2G); communication support: Supporting dozens of communication rules and is able to communicate with various integrated automation equipment.图片30.jpg


    ●It is applicable in the power industry and the 6-66kV system of the large-scale mine enterprises.

    The material of the epoxy cast dry-type transformer is of good quality and scientific formula which adopts the advanced production testing equipment and is produced according to severe technology. The product is provided with high reliability and long service life. The shell with different protection levels can be allocated according to different use condition.


    ●Product Model and Performance Parameter

    Product Model

    Performance Parameter

    SC (B) Series

    Voltage class: 6~35Kv; rated capacity: 30~2500kvar

     

    图片31.jpgIt is equipped with low loss, low noise, small volume, light weight, convenient transportation, simple and convenient installation; it is of damp resistance and small capacity on maintenance, and the iron core and clamp have been handled particularly which can be operated under multiple environment; it is of good heat dissipation and overload capacity, and the rated capacity of 120% can be output when it is cooled by the fan with low noise; the insulation materials such as the epoxy resin and glass fiber grid cloth adopted by the coil is provided with the character of automatic flameout.


    It is extensively used in the power transmission and distribution system, hotels, high-rise building, commercial centre, stadium, petrochemical plant, underground railway, station and airport, marine drilling platform and other places, especially the places closed to the load centre and where the special fire protection is required due to the limited installation space.